Specifications Table for FXCQ-MVE

FXCQ20MVE9 FXCQ25MVE9 FXCQ32MVE9 FXCQ40MVE9 FXCQ50MVE9 FXCQ63MVE9 FXCQ80MVE9 FXCQ125MVE9
Dimensions Unit Height mm 305 305 305 305 305 305 305 305
    Width mm 775 775 775 990 990 1,175 1,665 1,665
    Depth mm 600 600 600 600 600 600 600 600
Weight Unit kg 26 26 26 31 32 35 47 48
Casing Material   Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate Galvanised steel plate
Fan Air flow rate - 60Hz Cooling High m³/min   9     12 16.5 26 33
      Low m³/min   6.5     9 13 21 25
Refrigerant Type   R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Sound pressure level Cooling High dBA   34 (11), 36 (12)     34 (11), 37 (12) 37 (11), 39 (12) 39 (11), 41 (12) 44 (11), 46 (12)
Piping connections Liquid Type   Flare connection   Flare connection Flare connection        
    OD mm 6.35   6.35 6.35        
  Gas Type   Flare connection   Flare connection Flare connection        
    OD mm 12.7   12.7 12.7        
  Drain   VP25 (I.D. 25/O.D. 32)   VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32)        
Decoration panel Model   BYBC32GJW1, BYBC32G-W1 BYBC32GJW1, BYBC32G-W1 BYBC32GJW1, BYBC32G-W1 BYBC50GJW1, BYBC50G-W1 BYBC50GJW1, BYBC50G-W1 BYBC63GJW1, BYBC63G-W1 BYBC125GJW1, BYBC125G-W1 BYBC125GJW1, BYBC125G-W1
  Colour   White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5) White (10Y9/0.5)
  Dimensions Height mm 53 53 53 53 53 53 53 53
    Width mm 1,030 1,030 1,030 1,245 1,245 1,430 1,920 1,920
    Depth mm 680 680 680 680 680 680 680 680
  Weight kg 8 8 8 8.5 8.5 9.5 12 12
Power supply Name   VE VE VE VE VE VE VE VE
  Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Frequency Hz 50/60 50/60 50/60 50/60 50/60 50/60 50/60 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220 220-240/220
Current - 50Hz Maximum fuse amps (MFA) A 15   15 15        
Notes (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) (1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal) Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
  (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) (2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal) Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
  (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. (3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat. Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
  (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
  (5) - Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. (5) - Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%. Maximum allowable voltage range variation between phases is 2%.
  (6) - MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA (6) - MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA MCA/MFA: MCA = 1.25 x FLA
  (7) - MFA ≤ 4 x FLA MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA (7) - MFA ≤ 4 x FLA MFA ≤ 4 x FLA MFA ≤ 4 x FLA MFA ≤ 4 x FLA MFA ≤ 4 x FLA
  (8) - Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A (8) - Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A Next lower standard fuse rating minimum 15A
  (9) - Select wire size based on the value of MCA Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA (9) - Select wire size based on the value of MCA Select wire size based on the value of MCA Select wire size based on the value of MCA Select wire size based on the value of MCA Select wire size based on the value of MCA
  (10) - Instead of a fuse, use a circuit breaker Instead of a fuse, use a circuit breaker (10) - Instead of a fuse, use a circuit breaker (10) - Instead of a fuse, use a circuit breaker Instead of a fuse, use a circuit breaker Instead of a fuse, use a circuit breaker Instead of a fuse, use a circuit breaker Instead of a fuse, use a circuit breaker
Power input - 50Hz Cooling Nom. kW   92 (1)     130 (1) 161 (1) 209 (1) 256 (1)
  Heating Nom. kW   59 (2)     97 (2) 126 (2) 176 (2) 223 (2)
Power input - 60Hz Cooling Nom. kW   95 (1)     132 (1) 157 (1) 216 (1) 278 (1)
  Heating Nom. kW   62 (2)     99 (2) 124 (2) 183 (2) 245 (2)
Fan Air flow rate - 50Hz Cooling High m³/min   9     12 16.5 26 33
      Low m³/min   6.5     9 13 21 25
Sound pressure level Cooling Low dBA   29 (11), 30 (12)     29 (11), 32 (12) 32 (11), 34 (12) 34 (11), 36 (12) 38 (11), 40 (12)
Piping connections Liquid Type     Flare connection     Flare connection Flare connection Flare connection Flare connection
    OD mm   6.35     6.35 9.52 9.52 9.52
  Gas Type     Flare connection     Flare connection Flare connection Flare connection Flare connection
    OD mm   12.7     12.7 15.9 15.9 15.9
  Drain     VP25 (I.D. 25/O.D. 32)     VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32) VP25 (I.D. 25/O.D. 32)