Specifications Table for GD XLS

GD_XLS_UK_403788 GD_XLS_EU_403764
Classification acc. EN 23953-2 M1 M1
Climate class acc. EN 23953-2 6 6
Energy efficiency index EEI % 20.5 20.5
Use Display & Sale Display & Sale
Dimensions Gross content l 713 (0.000) 713 (0.000)
  Net content l 372 (2.000) 372 (2.000)
  Total display area (TDA) 1.82 (2.000) 1.82 (2.000)
  Length Outside mm 1,195 1,195
  Depth Outside mm 655 655
  Height Outside mm 1,973 1,973
  Shelf depth mm 320 320
Net weight kg 181 (2.000) 181 (2.000)
Gross weight kg 210 (2.000) 210 (2.000)
Operation range Ambient temperature Min. °C 16 16
    Max. °C 27 27
  Relative humidity % 70 or less 70 or less
  Product temperature Min. °C -1 -1
    Max. °C 5 5
  Sound pressure in 1m distance dB(A) 50 50
  Blowing agent   R-601 (HC) GWP 5 R-601 (HC) GWP 5
Daily energy consumption Edaily kWh/day 5.80 (1.000) 5.80 (1.000)
Annual energy consumption AE kWh/a 2,117.00 2,117.00
Rejected heat capacity W 242 242
Dehumidification Liter/day 0 0
Refrigerant Type   R-290 R-290
  GWP   3 3
  Charge g 120 120
  Max. allowable operating pressure bar 30 30
Power supply Voltage V 220-240 220-240
  Frequency Hz 50 50
  Nominal power acc. EN 60335-2-89 W 390 390
  Nominal current acc. EN 60335-2-89 A 2.2 2.2
  Nominal power LED W 50 50
  Fuse protection   RCBO, 30mA, C16 RCBO, 30mA, C16
  Cord length mm 3,000 3,000
Notes (1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2 (1) - Energy test results are declared for climate class 3, test procedure according to EN 23953-2
  (2) - With process-related interior fitting (2) - With process-related interior fitting