Specifications Table for MC707

MC707VM-W MC707VM-S
Application Desktop Type Desktop Type
Capacity m³/min 7.0 7.0
Casing Colour   White Silver
Dimensions Unit Height mm 533 533
    Width mm 425 425
    Depth mm 213 213
Weight Unit kg 8.7 8.7
Applicable room area 48 48
Air purifying operation Power input Turbo kW 0.055 0.055
    H kW 0.023 0.023
    M kW 0.014 0.014
    L kW 0.010 0.010
    Silent kW 0.008 0.008
  Deodorizing efficiency (JEM 1467*) Turbo % 95 95
  Dust collection efficiency Turbo % 89 89
Sound pressure level Air purifying operation Turbo dBA 47.0 47.0
    High dBA 38.0 38.0
    Medium dBA 31.0 31.0
    Low dBA 24.0 24.0
    Silent dBA 16.0 16.0
Fan Air flow rate Air purifying operation Turbo m³/h 420 420
      High m³/h 285 285
      Medium m³/h 180 180
      Low m³/h 120 120
      Silent m³/h 60 60
Air flow control Stages   5 5
Dust collecting method Electrostatic dust collection filter, Plasma ionizer (electrostatic dust collection) Electrostatic dust collection filter, Plasma ionizer (electrostatic dust collection)
Deodorizing method Deodorising catalyst, Flash streamer, Titanium apatite photocatalytic filter Deodorising catalyst, Titanium apatite photocatalytic filter, Flash streamer
Bacteria filtering method Titanium apatite photocatalytic filter, Bio-antibody filter, Flash streamer Titanium apatite photocatalytic filter, Bio-antibody filter, Flash streamer
Safety devices Item 01   Safety switch (operation stops when the front panel opens) Safety switch (operation stops when the front panel opens)
Standard Accessories Photocatalytic pleated Filter 7 7
  Operation manual 1 1
  Bio-antibody Filter 1 1
Power cord m 2.0 2.0
Power supply Name   VM VM
  Phase   1~ 1~
  Frequency Hz 50/60 50/60
  Voltage V 220-240/220-230 220-240/220-230
Running current Air purifying operation Turbo A 0.48 0.48
    High A 0.22 0.22
    Medium A 0.14 0.14
    Low A 0.10 0.10
    Silent A 0.08 0.08
Notes Deodorizing efficiency means the combined removal rate of amonia, acetaldehyde and acetic acid after burning five cigarettes in a 1m³ airtight container and running the air purifier at rated air flow for one minute Deodorizing efficiency means the combined removal rate of amonia, acetaldehyde and acetic acid after burning five cigarettes in a 1m³ airtight container and running the air purifier at rated air flow for one minute
  Sound pressure levels are the average of values measured at 1m away from the front, left, right and top of the unit (this is equal to the value in an anechoic chamber). Sound pressure levels are the average of values measured at 1m away from the front, left, right and top of the unit (this is equal to the value in an anechoic chamber).
  Other signs: operation switch: stop; air flow rate indicator Other signs: operation switch: stop; air flow rate indicator
Standard Accessories Infrared remote control   1