FHA50AVEB9 / RXS50L2V1B |
FHA50AVEB99 / RXS50L2V1B |
FHA60AVEB9 / RXS60L2V1B |
FHA60AVEB99 / RXS60L2V1B |
Cooling capacity
|
Nom.
|
kW
|
5.00
|
5.00
|
5.70
|
5.70
|
Space cooling
|
SEER
|
|
5.87
|
5.87
|
6.02
|
6.02
|
|
Annual energy consumption
|
kWh/a
|
298
|
298
|
332
|
332
|
|
Capacity
|
Pdesign
|
kW
|
5.00
|
5.00
|
5.70
|
5.70
|
|
Energy efficiency class
|
|
A+
|
A+
|
A+
|
A+
|
Space heating (Average climate)
|
Capacity
|
Pdesign
|
kW
|
4.35
|
4.35
|
4.71
|
4.71
|
|
SCOP/A
|
|
3.86
|
3.86
|
3.87
|
3.87
|
|
Energy efficiency class
|
|
A
|
A
|
A
|
A
|
|
Pdh Heating capacity at -10°
|
kW
|
3.85
|
|
4.08
|
|
Annual energy consumption
|
kWh/a
|
1,578
|
1,578
|
1,705
|
1,705
|
Nominal efficiency
|
Annual energy consumption
|
kWh
|
765
|
765
|
861
|
861
|
|
EER
|
|
3.27
|
3.27
|
3.31
|
3.31
|
|
COP
|
|
3.35
|
3.35
|
3.32
|
3.32
|
|
Energy labeling Directive
|
Cooling
|
|
A
|
A
|
A
|
A
|
|
|
Heating
|
|
C
|
C
|
C
|
C
|
Heating capacity
|
Nom.
|
kW
|
6.00
|
6.00
|
7.20
|
7.20
|
Notes
|
(1) - "Code du travail" applications are non-public buildings (example offices).
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(1) - "Code du travail" applications are non-public buildings (example offices).
|
(1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
(2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
|
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
(3) - See separate drawing for operation range
|
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|
(4) - See separate drawing for electrical data
|