Specifications Table for FTXS-K / RXS-K

FTXS20K2V1B / RXS20K2V1B FTXS20K2V1B / RXS20K3V1B FTXS25K2V1B / RXS25K2V1B FTXS25K2V1B / RXS25K3V1B FTXS35K2V1B / RXS35K2V1B FTXS42K2V1B / RXS42K2V1B FTXS50K2V1B / RXS50K2V1B
Cooling capacity Min. kW 1.3 1.3 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2.0 (3) 2.0 (2) 2.5 (3) 2.5 (2) 3.50 (2) 4.20 (2) 5.00 (2)
  Max. kW 2.8 2.8 3.2 3.2 4.0 5.0 5.3
Heating capacity Min. kW 1.3 1.3 1.3 1.3 1.4 1.7 1.7
  Nom. kW 2.5 (4) 2.5 (3) 2.8 (4) 2.8 (3) 4.00 (3) 5.40 (3) 5.8 (3)
  Max. kW 4.3 4.3 4.7 4.7 5.2 6.0 6.5
Nominal efficiency EER   4.65 4.65 4.39 4.39 4.17 3.56 3.55
  COP   4.55 4.55 4.52 4.52 4.76 4.12 4.00
  Annual energy consumption kWh 215 215 285 285 420 590 705
  Energy labeling Directive Cooling   A A A A A A A
    Heating   A A A A A A A
Space cooling Capacity Pdesign kW   2.00   2.50 3.50 4.20 5.00
  Energy efficiency class   A+   A++ A++ A++ A++
  SEER   5.71   6.37 6.97 6.60 6.60
  Annual energy consumption kWh/a   123   137 176 223 265
Space heating (Average climate) Capacity Pdesign kW   2.30   2.50 3.60 4.00 4.60
  Energy efficiency class   A++   A++ A++ A+ A+
  SCOP/A   4.75   4.63 4.71 4.09 4.10
  Annual energy consumption kWh/a   678   756 1,071 1,371 1,571
Piping connections Drain OD Mm 18.0 18.0 18.0 18.0 18 18 18
  Gas OD Mm 9.5 9.5 9.5 9.5 9.5 9.5 12.7
  Liquid OD Mm 6.35 6.35 6.35 6.35 6.35 6.35 6.35
Notes (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - Energy label: scale from A (most efficient) to G (less efficient) (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only (1) - EER/COP according to Eurovent 2012, for use outside EU only
  (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (2) - Annual energy consumption: based on average use of 500 running hours per year at full load (nominal conditions) (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (2) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m
  (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Cooling: indoor temp. 27°CDB, 19.0°CWB; outdoor temp. 35°CDB, 24°CWB; equivalent piping length: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (3) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m
  (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - 220V (4) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 5m (4) - 220V (4) - 220V (4) - 220V (4) - 220V
  (5) - 220V (5) - 230V (5) - 220V (5) - 230V (5) - 230V (5) - 230V (5) - 230V
  (6) - 230V (6) - 240V (6) - 230V (6) - 240V (6) - 240V (6) - 240V (6) - 240V
  (7) - 240V (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - 240V (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load (7) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load
  (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load   (8) - Nominal efficiency: cooling at 35°/27° nominal load, heating at 7°/20° nominal load