Specifications Table for ATXP-P / ARXP-M

ATXP20P5V1B / ARXP20M5V1B ATXP25P5V1B / ARXP25M5V1B ATXP35P5V1B / ARXP35M5V1B
Outdoor unit ARXP20M5V1B ARXP25M5V1B ARXP35M5V1B
Cooling capacity Min. kW 1.3 1.3 1.3
  Nom. kW 2.00 2.50 3.50
  Max. kW 2.6 3.0 4.0
Heating capacity Min. kW 1.30 1.30 1.30
  Nom. kW 2.50 3.00 4.00
  Max. kW 3.50 4.00 4.80
Nominal efficiency EER   3.71 3.71 3.46
  COP   4.77 4.36 4.02
  Energy labeling Directive Cooling   A A A
    Heating   A A A
Space cooling Energy efficiency class   A++ A++ A++
  Capacity Pdesign kW 2.00 2.50 3.50
  SEER   6.90 6.90 6.90
  Annual energy consumption kWh/a 101 127 178
Space heating (Average climate) Energy efficiency class   A++ A++ A++
  Capacity Pdesign kW 2.20 2.40 2.80
  SCOP/A   4.64 4.60 4.62
  Pdh Heating capacity at -10° kW 1.98 2.09 2.32
  Annual energy consumption kWh/a 663 730 847
Energy Efficiency Range A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data (1) - See separate drawing for electrical data
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. Data for high efficiency series, Eurovent certified
  (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series (3) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. Data for standard efficiency series