| EBLQ05CAV3 | EBLQ07CAV3 | |||||
|---|---|---|---|---|---|---|
| Sound pressure level | Heating | Nom. | dBA | 48 (8) | 49 (8) | |
| Cooling | Nom. | dBA | 48 (8) | 50 (8) | ||
| Refrigerant | GWP | 2,088 | 2,088 | |||
| Charge | kg | 1.30 | 1.45 | |||
| Type | R-410A | R-410A | ||||
| Operation range | Cooling | Ambient | Max. | °CDB | 43.0 | 43.0 |
| Min. | °CDB | 10.0 | 10.0 | |||
| Water side | Max. | °C | 22.0 | 22.0 | ||
| Min. | °C | 5.00 (5) | 5.00 (5) | |||
| Heating | Water side | Max. | °C | 55.0 | 55.0 | |
| Min. | °C | 15 (4) | 15 (4) | |||
| Domestic hot water | Water side | Max. | °C | 80 (7) | 80 (7) | |
| Min. | °C | 25 | 25 | |||
| Ambient | Min. | °CDB | -25.0 (6) | -25.0 (6) | ||
| Max. | °CDB | 35.0 (6) | 35.0 (6) | |||
| Cooling capacity | Nom. | kW | 3.88 (1), 3.99 (2) | 5.20 (1), 5.15 (2) | ||
| Power input | Cooling | Nom. | kW | 0.950 (1), 1.93 (2) | 1.37 (1), 2.69 (2) | |
| Heating | Nom. | kW | 0.880 (1), 1.13 (2) | 1.55 (1), 2.45 (2) | ||
| Sound power level | Heating | Nom. | dBA | 61 | 62 | |
| Cooling | Nom. | dBA | 63.0 | 63.0 | ||
| COP | 5.00 (1), 3.58 (2) | 4.52 (1), 3.42 (2) | ||||
| Dimensions | Unit | Width | mm | 1,090 | 1,090 | |
| Depth | mm | 350 | 350 | |||
| Height | mm | 735 | 735 | |||
| Weight | Unit | kg | 76.0 | 80.0 | ||
| Space heating | Average climate water outlet 35°C | General | ηs (Seasonal space heating efficiency) | % | 175 | 164 |
| Seasonal space heating eff. class | A++ | A++ | ||||
| SCOP | 4.45 | 4.18 | ||||
| Average climate water outlet 55°C | General | Seasonal space heating eff. class | A++ | A++ | ||
| ηs (Seasonal space heating efficiency) | % | 126 | 126 | |||
| SCOP | 3.22 | 3.22 | ||||
| Fan | Air flow rate | Heating | High | m³/min | 45.0 | 47.0 |
| Cooling | High | m³/min | 52.5 | 52.5 | ||
| EER | 4.07 (1), 2.07 (2) | 3.80 (1), 2.10 (2) | ||||
| Heating capacity | Nom. | kW | 4.40 (1), 4.03 (2) | 7.00 (1), 6.90 (2) | ||
| Power supply | Phase | 1~ | 1~ | |||
| Name | V3 | V3 | ||||
| Frequency | Hz | 50 | 50 | |||
| Voltage | V | 230 | 230 | |||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| (3) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | (3) - PED unit category: excluded from scope of PED due to article 1, item 3.6 of 97/23/EC | |||||
| (4) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C | (4) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C | |||||
| (5) - For more details on standard accessories refer to Installation/operation manual | (5) - For more details on standard accessories refer to Installation/operation manual | |||||
| (6) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. | (6) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. | |||||
| (7) - > 50°C BSH only, no heatpump operation | (7) - > 50°C BSH only, no heatpump operation | |||||
| (8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (8) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | |||||
| (9) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (9) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | |||||
| (10) - Including piping + PHE; excluding expansion vessel | (10) - Including piping + PHE; excluding expansion vessel | |||||
| (11) - Daikin Altherma inverter controlled compressor starting current always <= max. running current | (11) - Daikin Altherma inverter controlled compressor starting current always <= max. running current | |||||