| EDLQ05CAV3 | EDLQ07CAV3 | |||||
|---|---|---|---|---|---|---|
| Heating capacity | Nom. | kW | 4.4, 4.03 | 7, 6.9 | ||
| Power input | Heating | Nom. | kW | 0.88, 1.13 | 1.55, 2.02 | |
| COP | 5, 3.58 | 4.52, 3.42 | ||||
| Dimensions | Unit | Height | mm | 735 | 735 | |
| Width | mm | 1090 | 1090 | |||
| Depth | mm | 350 | 350 | |||
| Weight | Unit | kg | 76 | 80 | ||
| Fan | Air flow rate | Heating | High | m³/min | 45.0 | 47.0 |
| Operation range | Heating | Water side | Min. | °C | 15 | 15 |
| Max. | °C | 55.0 | 55.0 | |||
| Domestic hot water | Ambient | Min. | °CDB | -25.0 | -25.0 | |
| Max. | °CDB | 35.0 | 35.0 | |||
| Water side | Min. | °C | 25 | 25 | ||
| Max. | °C | 80 | 80 | |||
| Sound power level | Heating | Nom. | dBA | 61 | 62 | |
| Sound pressure level | Heating | Nom. | dBA | 48 | 49 | |
| Refrigerant | Type | R-410A | R-410A | |||
| GWP | 2088 | 2088 | ||||
| Charge | kg | 1.3 | 1.45 | |||
| Charge | tCO2Eq | 2.714 | 3.027 | |||
| Space heating | Average climate water outlet 55°C | General | SCOP | 3.2 | 3.2 | |
| Seasonal space heating eff. class | A++ | A++ | ||||
| Average climate water outlet 35°C | General | SCOP | 4.39 | 4.14 | ||
| Seasonal space heating eff. class | A++ | A++ | ||||
| Power supply | Name | V3 | V3 | |||
| Phase | 1~ | 1~ | ||||
| Frequency | Hz | 50 | 50 | |||
| Voltage | V | 230 | 230 | |||
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | ||||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | |||||
| (3) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C | (3) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C | |||||
| (4) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. | (4) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. | |||||
| (5) - > 50°C BSH only, no heatpump | (5) - > 50°C BSH only, no heatpump | |||||
| (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. | |||||
| (7) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | (7) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). | |||||
| (8) - Including piping + PHE; excluding expansion vessel | (8) - Including piping + PHE; excluding expansion vessel | |||||
| (9) - Daikin Altherma inverter controlled compressor starting current always <= max. running current | (9) - Daikin Altherma inverter controlled compressor starting current always <= max. running current | |||||