Specifications Table for EDLQ-CV3

EDLQ05CAV3 EDLQ07CAV3
Heating capacity Nom. kW 4.4, 4.03 7, 6.9
Power input Heating Nom. kW 0.88, 1.13 1.55, 2.02
COP 5, 3.58 4.52, 3.42
Dimensions Unit Height mm 735 735
    Width mm 1090 1090
    Depth mm 350 350
Weight Unit kg 76 80
Fan Air flow rate Heating High m³/min 45.0 47.0
Operation range Heating Water side Min. °C 15 15
      Max. °C 55.0 55.0
  Domestic hot water Ambient Min. °CDB -25.0 -25.0
      Max. °CDB 35.0 35.0
    Water side Min. °C 25 25
      Max. °C 80 80
Sound power level Heating Nom. dBA 61 62
Sound pressure level Heating Nom. dBA 48 49
Refrigerant Type   R-410A R-410A
  GWP   2088 2088
  Charge kg 1.3 1.45
  Charge tCO2Eq 2.714 3.027
Space heating Average climate water outlet 55°C General SCOP   3.2 3.2
      Seasonal space heating eff. class   A++ A++
  Average climate water outlet 35°C General SCOP   4.39 4.14
      Seasonal space heating eff. class   A++ A++
Power supply Name   V3 V3
  Phase   1~ 1~
  Frequency Hz 50 50
  Voltage V 230 230
Notes (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C)
  (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C )
  (3) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C (3) - Lower if back-up heater is installed; In case of no back-up heater, then heat pump operation starts at 10°C
  (4) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range. (4) - Operation range domestic hot water (outdoor unit): range increase by support booster heater or backup heater. See separate drawing for operation range.
  (5) - > 50°C BSH only, no heatpump (5) - > 50°C BSH only, no heatpump
  (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information. (6) - The sound pressure level is measured via a microphone at a certain distance from the unit. It is a relative value depending on the distance and acoustic environment. Refer to sound spectrum drawing for more information.
  (7) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation). (7) - Operation area is extended to lower flow rates only in case the unit operates with heat pump only. (Not in startup, no BUH operation, no defrost operation).
  (8) - Including piping + PHE; excluding expansion vessel (8) - Including piping + PHE; excluding expansion vessel
  (9) - Daikin Altherma inverter controlled compressor starting current always <= max. running current (9) - Daikin Altherma inverter controlled compressor starting current always <= max. running current