| EHVX04S18CB3V / ERLQ004CAV3 | EHVX08S18CB3V / ERLQ006CAV3 | EHVX08S26CB9W / ERLQ006CAV3 | EHVX08S18CB3V / ERLQ008CAV3 | EHVX08S26CB9W / ERLQ008CAV3 | EHVX11S18CB3V / ERLQ011CAV3 | EHVX11S26CB9W / ERLQ011CAV3 | EHVX16S18CB3V / ERLQ014CAV3 | EHVX16S26CB9W / ERLQ014CAV3 | EHVX16S18CB3V / ERLQ016CAV3 | EHVX16S26CB9W / ERLQ016CAV3 | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Domestic hot water heating | General | Declared load profile | L | L | XL | L | XL | L | XL | L | XL | L | XL | |
| Average climate | Water heating energy efficiency class | A | A | A | A | A | A | A | A | A | A | A | ||
| COP | 5.04 (1), 3.58 (2) | 4.74 (1), 3.56 (2) | 4.74 (1), 3.56 (2) | 4.45 (1), 3.42 (2) | 4.45 (1), 3.42 (2) | 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) | 4.60 (1), 2.75 (3), 3.55 (2), 2.10 (4) | 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) | 4.30 (1), 2.65 (3), 3.32 (2), 2.08 (4) | 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) | 4.25 (1), 2.64 (3), 3.26 (2), 2.09 (4) | |||
| Cooling capacity | Nom. | kW | 4.08 (1), 4.17 (2) | 5.88 (1), 4.84 (2) | 5.88 (1), 4.84 (2) | 6.20 (1), 5.36 (2) | 6.20 (1), 5.36 (2) | 12.1 (1), 11.7 (2) | 12.1 (1), 11.7 (2) | 12.7 (1), 12.6 (2) | 12.7 (1), 12.6 (2) | 13.8 (1), 13.1 (2) | 13.8 (1), 13.1 (2) | |
| Min. | kW | 2.00 (1), 2.00 (2) | 2.50 (1), 2.50 (2) | 2.50 (1), 2.50 (2) | 2.50 (1), 2.50 (2) | 2.50 (1), 2.50 (2) | ||||||||
| EER | 4.55 (1), 2.32 (2) | 3.89 (1), 2.34 (2) | 3.89 (1), 2.34 (2) | 3.79 (1), 2.29 (2) | 3.79 (1), 2.29 (2) | 3.98 (1), 2.72 (2) | 3.98 (1), 2.72 (2) | 3.96 (1), 2.47 (2) | 3.96 (1), 2.47 (2) | 3.69 (1), 2.29 (2) | 3.69 (1), 2.29 (2) | |||
| Heating capacity | Nom. | kW | 4.40 (1), 4.03 (2) | 6.00 (1), 5.67 (2) | 6.00 (1), 5.67 (2) | 7.40 (1), 6.89 (2) | 7.40 (1), 6.89 (2) | 11.2 (1), 11.0 (2) | 11.2 (1), 11.0 (2) | 14.5 (1), 13.6 (2) | 14.5 (1), 13.6 (2) | 16.0 (1), 15.2 (2) | 16.0 (1), 15.2 (2) | |
| Min. | kW | 1.80 (1) | 1.80 (1) | 1.80 (1) | 1.80 (1) | 1.80 (1) | ||||||||
| Max. | kW | 5.12 (1), 4.90 (2) | 8.35 (1), 7.95 (2) | 8.35 (1), 7.95 (2) | 10.0 (1), 9.53 (2) | 10.0 (1), 9.53 (2) | 8.60 (3), 8.60 (4) | 8.60 (3), 8.60 (4) | 10.6 (3), 10.8 (4) | 10.6 (3), 10.8 (4) | 11.4 (3), 10.9 (4) | 11.4 (3), 10.9 (4) | ||
| Power input | Heating | Max. | kW | 3.13 (3), 4.10 (4) | 3.13 (3), 4.10 (4) | 4.00 (3), 5.19 (4) | 4.00 (3), 5.19 (4) | 4.32 (3), 5.22 (4) | 4.32 (3), 5.22 (4) | |||||
| Nom. | kW | 0.870 (1), 1.13 (2) | 1.27 (1), 1.59 (2) | 1.27 (1), 1.59 (2) | 1.66 (1), 2.01 (2) | 1.66 (1), 2.01 (2) | 2.43 (1), 3.10 (2) | 2.43 (1), 3.10 (2) | 3.37 (1), 4.10 (2) | 3.37 (1), 4.10 (2) | 3.76 (1), 4.66 (2) | 3.76 (1), 4.66 (2) | ||
| Cooling | Nom. | kW | 0.900 (1), 1.80 (2) | 1.51 (1), 2.07 (2) | 1.51 (1), 2.07 (2) | 1.64 (1), 2.34 (2) | 1.64 (1), 2.34 (2) | 3.05 (1), 4.31 (2) | 3.05 (1), 4.31 (2) | 3.21 (1), 5.08 (2) | 3.21 (1), 5.08 (2) | 3.74 (1), 5.73 (2) | 3.74 (1), 5.73 (2) | |
| Notes | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | (1) - Condition 1: cooling Ta 35°C - LWE 18°C (DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 35°C (DT = 5°C) | |||
| (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | (2) - Condition 2: cooling Ta 35°C - LWE 7°C ( DT = 5°C); heating Ta DB/WB 7°C/6°C - LWC 45°C ( DT = 5°C ) | ||||
| (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Tamb 35°C - LWE 7°C (DT=5°C) | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | (3) - Condition 3: heating Ta DB -7°C (RH85%) - LWC 35°C | ||||
| (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Tamb 35°C - LWE 18°C (DT=5°C) | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | (4) - Condition 4: heating Ta DB -7°C (RH85%) - LWC 45°C | ||||
| (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (5) - Tamb 35°C - LWE 7°C (DT=5°C) | (5) - Tamb 35°C - LWE 7°C (DT=5°C) | (5) - Tamb 35°C - LWE 7°C (DT=5°C) | (5) - Tamb 35°C - LWE 7°C (DT=5°C) | (5) - Tamb 35°C - LWE 7°C (DT=5°C) | (5) - Tamb 35°C - LWE 7°C (DT=5°C) | ||||
| (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (6) - Tamb 35°C - LWE 18°C (DT=5°C) | (6) - Tamb 35°C - LWE 18°C (DT=5°C) | (6) - Tamb 35°C - LWE 18°C (DT=5°C) | (6) - Tamb 35°C - LWE 18°C (DT=5°C) | (6) - Tamb 35°C - LWE 18°C (DT=5°C) | (6) - Tamb 35°C - LWE 18°C (DT=5°C) | ||||
| (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | (7) - DB/WB 7°C/6°C - LWC 35°C (DT=5°C) | |||||||||
| (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | (8) - DB/WB 7°C/6°C - LWC 45°C (Dt=5°C) | |||||||||