Specifications Table for FBA-A(9) / RZQSG-L(8)Y1

FBA100A2VEB / RZQSG100L8Y1B FBA35A2VEB9 / FBA35A2VEB9 / FBA35A2VEB9 / RZQSG100L8Y1B FBA50A2VEB9 / FBA50A2VEB9 / RZQSG100L8Y1B FBA125A2VEB / RZQSG125L8Y1B FBA35A2VEB9 / FBA35A2VEB9 / FBA35A2VEB9 / FBA35A2VEB9 / RZQSG125L8Y1B FBA50A2VEB9 / FBA50A2VEB9 / FBA50A2VEB9 / RZQSG125L8Y1B FBA60A2VEB9 / FBA60A2VEB9 / RZQSG125L8Y1B FBA140A2VEB / RZQSG140L7Y1B
Cooling capacity Nom. kW 9.5 9.5 9.5 12.0 12.0 12.0 12.0 13.4
Space cooling SEER   5.96 5.75 5.10 5.47 4.80 4.80 4.80 5.23
  Annual energy consumption kWh/a 558 578 651 768 874 875 875 1,537
  Capacity Pdesign kW 9.50 9.50 9.50 12.00 12.00 12.00 12.00 13.40
  Energy efficiency class   A+ A+ A A A A B
Space heating (Average climate) Capacity Pdesign kW 7.60 7.60 7.60 7.60 7.60 7.60 7.60 11.57
  SCOP/A   4.15 3.80 3.80 4.01 3.80 3.80 3.80 3.81
  Energy efficiency class   A+ A A A+ A A A
  Annual energy consumption kWh/a 2,564 2,800 2,800 2,653 2,800 2,800 2,800 4,255
Nominal efficiency EER   3.35 3.28 3.06 3.23 3.04 2.94 2.83 2.28
  Annual energy consumption kWh 1,418 1,448 1,552 1,858 1,974   2,120
  COP   3.67 3.33 3.30 3.63 3.35   3.26 3.40
  Energy labeling Directive Cooling   A A B A B   C
    Heating   A C C A C   C
Heating capacity Nom. kW 10.8 10.8 10.8 13.5 13.5   13.5 15.5
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data