| FFA50A2VEB / RXS50L2V1B | FFA60A2VEB / RXS60L2V1B | ||||
|---|---|---|---|---|---|
| Cooling capacity | Nom. | kW | 5.00 | 5.70 | |
| Space cooling | SEER | 5.93 | 5.71 | ||
| Annual energy consumption | kWh/a | 295 | 349 | ||
| Capacity | Pdesign | kW | 5.00 | 5.70 | |
| Energy efficiency class | A+ | A+ | |||
| Space heating (Average climate) | Capacity | Pdesign | kW | 3.84 | 3.96 |
| SCOP/A | 3.90 | 4.04 | |||
| Energy efficiency class | A | A+ | |||
| Annual energy consumption | kWh/a | 1,378 | 1,373 | ||
| Piping connections | Liquid | OD | mm | 6.35 | 6.35 |
| Gas | OD | mm | 12.70 | 12.70 | |
| Drain | OD | mm | VP20 (External dia.26, Internal dia. 20) | VP20 (External dia.26, Internal dia. 20) | |
| Nominal efficiency | EER | 3.21 | 3.02 | ||
| Annual energy consumption | kWh | 780 | 945 | ||
| COP | 3.49 | 3.41 | |||
| Energy labeling Directive | Cooling | A | B | ||
| Heating | B | B | |||
| Heating capacity | Nom. | kW | 5.80 | 7.00 | |
| Notes | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. | |||
| (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. | ||||
| (3) - See separate drawing for operation range | (3) - See separate drawing for operation range | ||||
| (4) - See separate drawing for electrical data | (4) - See separate drawing for electrical data | ||||