Specifications Table for FTXM-A / RXM-A9

FTXM25A2V1B / RXM25A5V1B9 FTXM25A5V1B / RXM25A5V1B9 FTXM35A2V1B / RXM35A5V1B9 FTXM35A5V1B / RXM35A5V1B9 FTXM50A2V1B / RXM50A5V1B9 FTXM50A5V1B / RXM50A5V1B9
Cooling capacity Min. kW 0.9 0.9 0.9 0.9 1.7 1.7
  Nom. kW 2.5 2.5 3.5 3.5 5 5
  Max. kW 3.8 3.8 4.4 4.4 5.3 5.3
Heating capacity Min. kW 0.8 0.8 0.8 0.8 1.7 1.7
  Nom. kW 2.8 2.8 4 4 5.8 5.8
  Max. kW 5 5 5.5 5.5 6.5 6.5
Nominal efficiency EER   5.2 5.2 4.63 4.63 3.68 3.68
  COP   5 5 4.55 4.55 3.95 3.95
  Annual energy consumption kWh 240 240 378 378 679 679
  Energy labeling Directive Cooling   A A A A A A
    Heating   A A A A A A
Space cooling Energy efficiency class   A+++ A+++ A+++ A+++ A++ A++
  Capacity Pdesign kW 2.5 2.5 3.5 3.5 5 5
  SEER   9.47 9.47 9.25 9.25 7.8 7.8
  Annual energy consumption kWh/a 92 92 132 132 224 224
Space heating (Average climate) Energy efficiency class   A+++ A+++ A+++ A+++ A++ A++
  Capacity Pdesign kW 2.4 2.4 2.5 2.5 4.5 4.5
  SCOP/A   5.2 5.2 5.2 5.2 4.8 4.8
  Pdh Heating capacity at -10° kW 2.4 2.4 2.5 2.5 4.5 4.5
  Annual energy consumption kWh/a 647 647 673 673 1312 1312
Notes (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.
  (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range (3) - See separate drawing for operation range
  (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data (4) - See separate drawing for electrical data