Specifications Table for FTXM-R / RXM-A

FTXM20R2V1B / RXM20A5V1B FTXM20R5V1B / RXM20A5V1B FTXM25R2V1B / RXM25A5V1B FTXM25R5V1B / RXM25A5V1B FTXM35R2V1B / RXM35A5V1B FTXM35R5V1B / RXM35A5V1B FTXM42R2V1B / RXM42A5V1B FTXM42R5V1B / RXM42A5V1B FTXM50R2V1B / RXM50A5V1B FTXM60R2V1B / RXM60A5V1B FTXM71R2V1B / RXM71A5V1B
Cooling capacity Min. kW 1.30 1.30 1.30 1.30 1.40 1.40 1.7 1.7 1.70 1.70 2.30
  Nom. kW 2.00 2.00 2.50 2.50 3.40 3.40 4.2 4.2 5.00 6.00 7.10
  Max. kW 2.60 2.60 3.20 3.20 4.00 4.00 5 5 6.00 7.00 8.50
Heating capacity Min. kW 1.30 1.30 1.30 1.30 1.40 1.40 1.7 1.7 1.70 1.70 2.30
  Nom. kW 2.50 2.50 2.80 2.80 4.00 4.00 5.4 5.4 5.80 7.00 8.20
  Max. kW 3.50 3.50 4.70 4.70 5.20 5.20 6 6 7.70 8.00 10.20
Nominal efficiency EER   4.57 4.57 4.50 4.50 4.23 4.23 3.03 3.03 3.68 3.39 3.03
  COP   5.00 5.00 5.00 5.00 4.04 4.04 3.98 3.98 4.00 3.61 3.19
  Annual energy consumption kWh 219 219 278 278 402 402 693 693 679 885 1172
  Energy labeling Directive Cooling   A A A A A A B B A A B
    Heating   A A A A A A A A A A D
Space cooling Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A++ A++ A++
  Capacity Pdesign kW 2.00 2.00 2.50 2.50 3.40 3.40 4.2 4.2 5.00 6.00 7.10
  SEER   8.65 8.65 8.65 8.65 8.65 8.65 7.1 7.1 7.41 6.90 6.20
  Annual energy consumption kWh/a 81 81 101 101 137 137 207 207 236 304 401
Space heating (Average climate) Energy efficiency class   A+++ A+++ A+++ A+++ A+++ A+++ A++ A++ A++ A+ A+
  Capacity Pdesign kW 2.30 2.30 2.40 2.40 2.50 2.50 4 4 4.60 4.80 6.20
  SCOP/A   5.10 5.10 5.10 5.10 5.10 5.10 4.71 4.71 4.71 4.30 4.10
  Pdh Heating capacity at -10° kW 2.24 2.24 2.30 2.30 2.35 2.35 2.97 2.97 3.85 3.99 5.01
  Annual energy consumption kWh/a 631 631 659 659 686 686 1190 1190 1368 1562 2116
Energy Efficiency Range A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D A+++ ~ D     A+++ ~ D A+++ ~ D A+++ ~ D
Notes (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range (1) - See separate drawing for operation range
  (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data (2) - See separate drawing for electrical data
  (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (3) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m.
  (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (4) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m.