FXCQ20MVE9 |
FXCQ25MVE9 |
FXCQ32MVE9 |
FXCQ40MVE9 |
FXCQ50MVE9 |
FXCQ63MVE9 |
FXCQ80MVE9 |
FXCQ125MVE9 |
Standard Accessories
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
Operation manual
|
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
Installation manual
|
|
Paper pattern for installation
|
Paper pattern for installation
|
Paper pattern for installation
|
Paper pattern for installation
|
Paper pattern for installation
|
Paper pattern for installation
|
Paper pattern for installation
|
Paper pattern for installation
|
Paper pattern for installation
|
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
Washer for hanger bracket
|
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
Clamp metal
|
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
Drain hose
|
|
Insulation for fitting
|
Insulation for fitting
|
Insulation for fitting
|
Insulation for fitting
|
Insulation for fitting
|
Insulation for fitting
|
Insulation for fitting
|
Insulation for fitting
|
Insulation for fitting
|
|
Washer fixing plate
|
Washer fixing plate
|
Washer fixing plate
|
Washer fixing plate
|
Washer fixing plate
|
Washer fixing plate
|
Washer fixing plate
|
Washer fixing plate
|
Washer fixing plate
|
|
Sealing pads
|
Sealing pads
|
Sealing pads
|
Sealing pads
|
Sealing pads
|
Sealing pads
|
Sealing pads
|
Sealing pads
|
Sealing pads
|
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
Clamps
|
|
Screws
|
Screws
|
Screws
|
Screws
|
Screws
|
Screws
|
Screws
|
Screws
|
Screws
|
|
Washer
|
Washer
|
Washer
|
Washer
|
Washer
|
Washer
|
Washer
|
Washer
|
Washer
|
Refrigerant
|
Type
|
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
R-410A
|
Piping connections
|
Liquid
|
OD
|
mm
|
6.35
|
6.35
|
6.35
|
6.35
|
6.35
|
9.52
|
9.52
|
9.52
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Gas
|
OD
|
mm
|
12.7
|
12.7
|
12.7
|
12.7
|
12.7
|
15.9
|
15.9
|
15.9
|
|
|
Type
|
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
Flare connection
|
|
Drain
|
|
VP25 (I.D. 25/O.D. 32)
|
VP25 (I.D. 25/O.D. 32)
|
VP25 (I.D. 25/O.D. 32)
|
VP25 (I.D. 25/O.D. 32)
|
VP25 (I.D. 25/O.D. 32)
|
VP25 (I.D. 25/O.D. 32)
|
VP25 (I.D. 25/O.D. 32)
|
VP25 (I.D. 25/O.D. 32)
|
Dimensions
|
Unit
|
Width
|
mm
|
775
|
775
|
775
|
990
|
990
|
1,175
|
1,665
|
1,665
|
|
|
Depth
|
mm
|
600
|
600
|
600
|
600
|
600
|
600
|
600
|
600
|
|
|
Height
|
mm
|
305
|
305
|
305
|
305
|
305
|
305
|
305
|
305
|
Casing
|
Material
|
|
Galvanised steel plate
|
Galvanised steel plate
|
Galvanised steel plate
|
Galvanised steel plate
|
Galvanised steel plate
|
Galvanised steel plate
|
Galvanised steel plate
|
Galvanised steel plate
|
Weight
|
Unit
|
kg
|
26
|
26
|
26
|
31
|
32
|
35
|
47
|
48
|
Decoration panel
|
Weight
|
kg
|
8
|
8
|
8
|
8.5
|
8.5
|
9.5
|
12
|
12
|
|
Model
|
|
BYBC32GJW1, BYBC32G-W1
|
BYBC32GJW1, BYBC32G-W1
|
BYBC32GJW1, BYBC32G-W1
|
BYBC50GJW1, BYBC50G-W1
|
BYBC50GJW1, BYBC50G-W1
|
BYBC63GJW1, BYBC63G-W1
|
BYBC125GJW1, BYBC125G-W1
|
BYBC125GJW1, BYBC125G-W1
|
|
Dimensions
|
Height
|
mm
|
53
|
53
|
53
|
53
|
53
|
53
|
53
|
53
|
|
|
Depth
|
mm
|
680
|
680
|
680
|
680
|
680
|
680
|
680
|
680
|
|
|
Width
|
mm
|
1,030
|
1,030
|
1,030
|
1,245
|
1,245
|
1,430
|
1,920
|
1,920
|
|
Colour
|
|
White (10Y9/0.5)
|
White (10Y9/0.5)
|
White (10Y9/0.5)
|
White (10Y9/0.5)
|
White (10Y9/0.5)
|
White (10Y9/0.5)
|
White (10Y9/0.5)
|
White (10Y9/0.5)
|
Current - 50Hz
|
Maximum fuse amps (MFA)
|
A
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
15
|
Power supply
|
Phase
|
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
1~
|
|
Name
|
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
VE
|
|
Frequency
|
Hz
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
50/60
|
|
Voltage
|
V
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
220-240/220
|
Notes
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
(1) - Cooling: indoor temp. 27°CDB, 19°CWB; outdoor temp. 35°CDB; equivalent piping length: 7.5m (horizontal)
|
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
(2) - Heating: indoor temp. 20°CDB; outdoor temp. 7°CDB, 6°CWB; equivalent refrigerant piping: 7.5m (horizontal)
|
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
(3) - Capacities are net, including a deduction for cooling (an addition for heating) for indoor fan motor heat.
|
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
(4) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
|
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
(5) - Maximum allowable voltage range variation between phases is 2%.
|
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
(6) - MCA/MFA: MCA = 1.25 x FLA
|
|
(7) - MFA ≤ 4 x FLA
|
(7) - MFA ≤ 4 x FLA
|
(7) - MFA ≤ 4 x FLA
|
(7) - MFA ≤ 4 x FLA
|
(7) - MFA ≤ 4 x FLA
|
(7) - MFA ≤ 4 x FLA
|
(7) - MFA ≤ 4 x FLA
|
(7) - MFA ≤ 4 x FLA
|
|
(8) - Next lower standard fuse rating minimum 15A
|
(8) - Next lower standard fuse rating minimum 15A
|
(8) - Next lower standard fuse rating minimum 15A
|
(8) - Next lower standard fuse rating minimum 15A
|
(8) - Next lower standard fuse rating minimum 15A
|
(8) - Next lower standard fuse rating minimum 15A
|
(8) - Next lower standard fuse rating minimum 15A
|
(8) - Next lower standard fuse rating minimum 15A
|
|
(9) - Select wire size based on the value of MCA
|
(9) - Select wire size based on the value of MCA
|
(9) - Select wire size based on the value of MCA
|
(9) - Select wire size based on the value of MCA
|
(9) - Select wire size based on the value of MCA
|
(9) - Select wire size based on the value of MCA
|
(9) - Select wire size based on the value of MCA
|
(9) - Select wire size based on the value of MCA
|
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|
(10) - Instead of a fuse, use a circuit breaker
|