Specifications Table for FXHQ-A

FXHQ32AVEB8 FXHQ63AVEB8 FXHQ100AVEB8 FXHQ32AVEB9 (Archived) FXHQ63AVEB (Archived) FXHQ63AVEB9 (Archived) FXHQ100AVEB (Archived) FXHQ100AVEB9 (Archived)
Sound pressure level Heating At high fan speed dBA 36.0 37.0 44.0 36.0 37.0 37.0 44.0 44.0
    At low fan speed dBA 31.0 34.0 34.0 31.0 34.0 34.0 34.0 34.0
    At medium fan speed dBA 34.0 35.0 37.0 34.0 35.0 35.0 37.0 37.0
  Cooling At low fan speed dBA 31.0 34.0 34.0 31.0 34.0 34.0 34.0 34.0
    At high fan speed dBA 36.0 37.0 44.0 36.0 37.0 37.0 44.0 44.0
    At medium fan speed dBA 34.0 35.0 37.0 34.0 35.0 35.0 37.0 37.0
Standard Accessories Operation manual       Operation manual Operation manual Operation manual Operation manual Operation manual
  Installation manual       Installation manual Installation manual Installation manual Installation manual Installation manual
  Declaration of conformity       Declaration of conformity Declaration of conformity Declaration of conformity Declaration of conformity Declaration of conformity
  Drain hose 1 1 1 Drain hose Drain hose Drain hose Drain hose Drain hose
  Clamp metal       Clamp metal Clamp metal Clamp metal Clamp metal Clamp metal
  Washer for hanger bracket       Washer for hanger bracket Washer for hanger bracket Washer for hanger bracket Washer for hanger bracket Washer for hanger bracket
  Clamps       Clamps Clamps Clamps Clamps Clamps
  Joint insulating material       Joint insulating material Joint insulating material Joint insulating material Joint insulating material Joint insulating material
  Sealing material 6 6 6 Sealing material Sealing material Sealing material Sealing material Sealing material
  Installation pattern       Installation pattern Installation pattern Installation pattern Installation pattern Installation pattern
  Resin bushing 1 1 1 Resin bushing Resin bushing Resin bushing Resin bushing Resin bushing
  Wiring fixture 2 2 2 Wiring fixture Wiring fixture Wiring fixture Wiring fixture Wiring fixture
  Screw for wiring fixture       Screw for wiring fixture Screw for wiring fixture Screw for wiring fixture Screw for wiring fixture Screw for wiring fixture
Refrigerant GWP   2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5 2,087.5
  Type   R-410A R-410A R-410A R-410A R-410A R-410A R-410A R-410A
Power input - 50Hz Cooling At high fan speed kW 0.107 0.111 0.237 0.107 0.111 0.111 0.237 0.237
  Heating At high fan speed kW 0.107 0.111 0.237 0.107 0.111 0.111 0.237 0.237
Cooling capacity Total capacity At high fan speed kW 3.6 7.1 11.2 3.6 7.1 7.1 11.2 11.2
Piping connections Liquid OD mm 6.35 9.52 9.52 6.4 9.52 9.5 9.52 9.5
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
  Gas OD mm 12.7 15.9 15.9 12.7 15.9 15.9 15.9 15.9
    Type   Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection Flare connection
  Drain   VP20 VP20 VP20 VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26) VP20 (I.D. 20/O.D. 26)
Sound power level Cooling At high fan speed dBA 54.0 55.0 62.0 54 55 55 62 62
Air filter Type   Resin net Resin net Resin net Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance Resin net with mold resistance
Dimensions Unit Width mm 960 1,270 1,590 960 1,270 1,270 1,590 1,590
    Depth mm 690 690 690 690 690 690 690 690
    Height mm 235 235 235 235 235 235 235 235
Casing Material   Resin, sheet metal Resin, sheet metal Resin, sheet metal Resin Resin Resin Resin Resin
  Colour   Fresh White Fresh White Fresh White Fresh White Fresh White Fresh White Fresh White Fresh White
Weight Unit kg 27 35 42 24 33 33 39 39
Fan Air flow rate - 50Hz Cooling At high fan speed m³/min 14.0 20.0 29.5 14.0 20.0 20.0 29.5 29.5
      At low fan speed m³/min 10.0 14.0 19.0 10.0 14.0 14.0 19.0 19.0
Heating capacity Total capacity At high fan speed kW 4.0 8.0 12.5 4.0 8.0 8.0 12.5 12.5
Current - 50Hz Maximum fuse amps (MFA) A 16 16 16 16 16 16 16 16
Power supply Phase   1~ 1~ 1~ 1~ 1~ 1~ 1~ 1~
  Name         VE VE VE VE VE
  Frequency Hz 50/60 50/60 50/60 50/60 50 50/60 50 50/60
  Voltage V 220-240/220 220-240/220 220-240/220 220-240/220 220-240 220-240/220 220-240 220-240/220
Notes (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Nominal cooling capacities are based on: indoor temperature: 27°CDB, 19°CWB, outdoor temperature: 35°CDB, equivalent refrigerant piping: 5m, level difference: 0m. (1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits. (1) - Voltage range: units are suitable for use on electrical systems where voltage supplied to unit terminal is not below or above listed range limits.
  (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Nominal heating capacities are based on: indoor temperature: 20°CDB, outdoor temperature: 7°CDB, 6°CWB, equivalent refrigerant piping: 5m, level difference: 0m. (2) - Maximum allowable voltage range variation between phases is 2%. (2) - Maximum allowable voltage range variation between phases is 2%. (2) - Maximum allowable voltage range variation between phases is 2%. (2) - Maximum allowable voltage range variation between phases is 2%. (2) - Maximum allowable voltage range variation between phases is 2%.
  (3) - The sound power level is an absolute value indicating the power which a sound source generates. (3) - The sound power level is an absolute value indicating the power which a sound source generates. (3) - The sound power level is an absolute value indicating the power which a sound source generates. (3) - MCA/MFA: MCA = 1.25 x FLA (3) - MCA/MFA: MCA = 1.25 x FLA (3) - MCA/MFA: MCA = 1.25 x FLA (3) - MCA/MFA: MCA = 1.25 x FLA (3) - MCA/MFA: MCA = 1.25 x FLA
  (4) - Instead of a fuse, use a circuit breaker (4) - Instead of a fuse, use a circuit breaker (4) - Instead of a fuse, use a circuit breaker (4) - MFA ≤ 4 x FLA (4) - MFA ≤ 4 x FLA (4) - MFA ≤ 4 x FLA (4) - MFA ≤ 4 x FLA (4) - MFA ≤ 4 x FLA
  (5) - Select wire size based on the value of MCA (5) - Select wire size based on the value of MCA (5) - Select wire size based on the value of MCA (5) - Next lower standard fuse rating minimum 16A (5) - Next lower standard fuse rating minimum 16A (5) - Next lower standard fuse rating minimum 16A (5) - Next lower standard fuse rating minimum 16A (5) - Next lower standard fuse rating minimum 16A
  (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases (6) - Contains fluorinated greenhouse gases (6) - Select wire size based on the value of MCA (6) - Select wire size based on the value of MCA (6) - Select wire size based on the value of MCA (6) - Select wire size based on the value of MCA (6) - Select wire size based on the value of MCA
        (7) - Instead of a fuse, use a circuit breaker (7) - Instead of a fuse, use a circuit breaker (7) - Instead of a fuse, use a circuit breaker (7) - Instead of a fuse, use a circuit breaker (7) - Instead of a fuse, use a circuit breaker
        (8) - Contains fluorinated greenhouse gases (8) - Contains fluorinated greenhouse gases (8) - Contains fluorinated greenhouse gases (8) - Contains fluorinated greenhouse gases (8) - Contains fluorinated greenhouse gases
Standard Accessories Thermal insulation tube 2 2 2
  Wire clamp material 7 7 7
  Hose band 1 1 1
  Screws 2 2 2
  Washer 8 8 8
  General safety precautions 1 1 1
  Installation and operation manual 1 1 1
  Paper pattern for installation 1 1 1