RZASG100MUY |
RZASG125MUY |
RZASG140MUY |
Dimensions
|
Unité
|
Hauteur
|
mm
|
990
|
990
|
990
|
|
|
Largeur
|
mm
|
940
|
940
|
940
|
|
|
Profondeur
|
mm
|
320
|
320
|
320
|
Poids
|
Unité
|
kg
|
72
|
72
|
79
|
Compresseur
|
Type
|
|
Compresseur swing hermétique
|
Compresseur swing hermétique
|
Compresseur swing hermétique
|
Plage de fonctionnement
|
Rafraîchissement
|
Temp. ext.
|
Min.
|
°CBS
|
-15
|
-15
|
-15
|
|
|
|
Max.
|
°CBS
|
46
|
46
|
46
|
|
Chauffage
|
Temp. ext.
|
Min.
|
°CBH
|
-15
|
-15
|
-15
|
|
|
|
Max.
|
°CBH
|
15.5
|
15.5
|
15.5
|
Niveau de puissance sonore
|
Rafraîchissement
|
dBA
|
70
|
71
|
73
|
|
Chauffage
|
dBA
|
|
71 (1)
|
73 (1)
|
Niveau de pression sonore
|
Rafraîchissement
|
Nom.
|
dBA
|
53
|
53
|
54
|
|
Chauffage
|
Nom.
|
dBA
|
57
|
57
|
57
|
Réfrigérant
|
R-32
|
R-32
|
R-32
|
|
Charge
|
kg
|
2.6
|
2.6
|
2.9
|
|
Réfrigérant-=-PRP
|
|
675
|
675
|
675
|
|
Charge
|
tCO2Eq
|
1.76
|
1.76
|
1.96
|
Raccords de tuyauterie
|
Liquide
|
DE
|
mm
|
9.52
|
9.52
|
9.52
|
|
Gaz
|
DE
|
mm
|
15.9
|
15.9
|
15.9
|
|
Longueur de tuyauterie
|
Max.
|
UE - UI
|
m
|
50
|
50
|
50
|
|
|
Système
|
Équivalente
|
m
|
70
|
70
|
70
|
|
|
|
Préchargé d'usine jusqu'à
|
m
|
30
|
30
|
30
|
|
Charge de réfrigérant supplémentaire
|
kg/m
|
Voir le manuel d'installation
|
Voir le manuel d'installation
|
Voir le manuel d'installation
|
|
Dénivelé
|
UI - UE
|
Max.
|
m
|
30
|
30
|
30
|
|
|
UI - UI
|
Max.
|
m
|
0.5
|
0.5
|
0.5
|
Accessoires standard
|
Installation manual
|
1
|
1
|
1
|
|
Refrigerant label for F-gas regulation
|
1
|
1
|
1
|
|
General safety precautions
|
1
|
1
|
1
|
|
LOT10 Energy Label
|
1
|
1
|
1
|
|
Declaration of conformity
|
2
|
2
|
2
|
|
Tie-wraps
|
2
|
2
|
2
|
Alimentation électrique
|
Phase
|
|
3~
|
3~
|
3~
|
|
Fréquence
|
Hz
|
50
|
50
|
50
|
|
Alimentation électrique-=-Tension-=-V
|
V
|
380-415
|
380-415
|
380-415
|
Courant - 50 Hz
|
Courant - 50 Hz-=-Intensité maximale de fusible (MFA)-=-A
|
A
|
16
|
16
|
16
|
Remarques
|
(1) - Conforme à la norme ENER Lot 21
|
(1) - Conforme à la norme ENER Lot 21
|
(1) - Conforme à la norme ENER Lot 21
|
|
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
(2) - European/international technical standard setting the limits for harmonic currents produced by equipment connected to public low-voltage system with input current larger than 16A and ≤ 75A per phase.
|
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
(3) - Ssc: Short-circuit power
|
|
(4) - Norme technique internationale/européenne définissant les limites de courants harmoniques générés par les équipements connectés au système basse tension public avec un courant d'entrée ≤ 16 A par phase.
|
(4) - Norme technique internationale/européenne définissant les limites de courants harmoniques générés par les équipements connectés au système basse tension public avec un courant d'entrée ≤ 16 A par phase.
|
(4) - Norme technique internationale/européenne définissant les limites de courants harmoniques générés par les équipements connectés au système basse tension public avec un courant d'entrée ≤ 16 A par phase.
|